Peak Heating and Cooling Load Calculations Aligned with ASHRAE 183 using Buildings AI
Please fill out this form to access the webinar recording:
Phone Number
Code
By clicking this button, you submit your information to the webinar organizer, who will use it to communicate with you regarding this and other future relevant events. You agree to our Privacy Notice. Along with your details, we receive the address of the page you are on and your IP address.
Webinars

Peak Heating and Cooling Load Calculations Aligned with ASHRAE 183 using Buildings AI

Watch this webinar to discover how Buildings AI enables accurate, standards-aligned peak heating and cooling load calculations in full compliance with ASHRAE Standard 183, delivering transparent, audit-ready results without manual complexity.

2 speakersAaditya Ruikar and Praveen Kumar
Peak Heating and Cooling Load Calculations Aligned with ASHRAE 183 using Buildings AI
Webinar recording · 0:50 hr Read the transcript

Peak load calculations and ASHRAE Standard 183

In high-performance HVAC design, peak heating and cooling load calculations form the foundation for occupant comfort, energy efficiency, system reliability, and cost optimization. ASHRAE Standard 183 was developed to bring consistency, clarity, and accuracy to peak load calculations for all buildings except low-rise residential.

Despite its importance, applying ASHRAE 183 correctly can be challenging. Engineers must manage detailed inputs, zoning logic, schedules, weather data, and rigorous documentation requirements—often spread across spreadsheets and disconnected tools. Errors or assumptions made early in the process can lead to oversizing, undersizing, compliance issues, and costly redesigns.

This technical webinar focused on how Buildings AI simplifies and automates ASHRAE 183–aligned peak load calculations using a physics-based Heat Balance engine, smart zoning, and automated reporting—while keeping the engineer fully in control of design intent.

What We Covered

  • Understand how peak cooling and heating loads are defined, structured, and calculated for buildings using industry-aligned methods.
  • Learn how key inputs, internal and external heat gains, and system-level factors influence peak load results and accuracy. Explore how ASHRAE Standard 183 standardizes peak load calculations through a step-by-step walkthrough using Buildings AI.

Who should watch?

  • HVAC Engineers seeking accurate, standards-aligned peak heating and cooling load calculations.
  • MEP Consultants aiming to improve system sizing accuracy and streamline design documentation.
  • Building Performance and Energy Modeling Professionals focused on compliance, efficiency, and reliable load analysis.
Speakers

Featured speakers

Aaditya Ruikar
Aaditya RuikarProduct Manager, simulationHub

Aaditya Ruikar works As a Product Manager at CCTech, He is involved in developing and delivering high-fidelity technologies for various industries at affordable prices and plays role of domain expert. He also has a vision to make these technologies more accessible and user-friendly for better and efficient design outcomes.His interests lie in researching and simulating real world systems, particularly in the domains of engineering, physics and sustainable development. He likes to tackle challenges and work with others to find innovative solutions.

Praveen Kumar
Praveen KumarProduct Marketing Manager, simulationHub

Praveen is an IGBC Accredited Professional (IGBC AP) and a Mechanical Engineer with two decades of experience in Computational Fluid Dynamics (CFD), specializing in applications like HVAC, valves and building performance. Complemented by a Post Graduate Certification in Product Management from IIM Indore, his unique blend of a strong technical foundation and deep product knowledge allows him to seamlessly bridge the gap between engineering complexities and market needs to deliver impactful solutions.

Transcript

Webinar transcript

Intro to Buildings AI & simulationHub

Good evening, good morning everyone. Welcome to today's webinar on peak cooling load and heating load calculation in compliance with Ashray 183 standard. We are thrilled to have you with us for this session. This webinar is ideal for HVAC designers, MEP consultants and professionals involved in HVAC load calculation and building energy analysis. So yes privacy next slide. So let me introduce ourselves. So myself privacy, I'll be your host today. So I'm the product marketing manager at simulationHub. I have around 15 plus years of experience in simulation field especially buildings HVAC thermal comfort CFD simulations.

I'm delighted to introduce today's speaker privacy. He's the product manager at simulationHub particularly buildings air. He's involved in developing and delivering high fidelity technology very around various industries playing the role of domain expert. His interests lie in researching simulating researching and simulating real world systems particularly in the domain of engineering and sustainable development. So next so for those the next slide yeah for those who are new to this webinar series that we are conducting so and new to buildings a who we are okay so this is buildings a is our product we are from simulationHub I did one slide back so buildings a is the product which is a aentic AI platform for HVAC load calculation and energy modeling So it is powered by EnergyPlus engine in the back end and Autodesk platform services for data management and visualization of the models autodisk revit support revit model support integration and everything and AWS for cloud for running the simulation energy simulation and the simulationHub plat APIs you know yeah so going forward so to put it

To paint the picture. So, building J is a AI powered human in loop workflows for whole building simulation. So, it has for every it has tools for you know importing the drawing to BIM, load calculation, energy simulation, report assistant, data management. So, all sort of things including the CFD module. So u in all these workflows we try to bring AI assisted thing. So let me explain more in further slides. For example yeah moving forward. So in for example take PDF to BIM. So this is a AI powered agent that uses advanced image processing, computer vision and deep learning techniques to convert your drawing or you know floor plan image into beam models. So in the next so u throughout our like workflow the app you have AI assistant which lets you interact with your you know beam model and you can query in your natural language and thanks to autodisk a data management ACDM so that you know it provides all the required information and you can execute commands do the setup there's material assistance everything throughout the stage of the you know buildings a the problem you'll have this a assistant and towards the end there is like report assistant which assist you with the

Load calculation report you know report generation as well as the basis of design reports from u so so from the OPR so all sort of assistant will be there you know to assist you in the whole workflow throughout the workflow. So we have been conducting series of educational webinars from the past few months and those who have not attended those you can you know always catch up go towards go to this website simulation.com there under webinar section you'll be able to watch all the recordings and in this series we are bringing the new today's topic. Yeah. So which is peak heating and cooling load calculation and ashray 180° complent. So with this I'll hand it over to privacy. privacy over to you. You can yeah jump into the topic.

Okay. Thank you. Thank you privacy for the great introduction of buildings and its AI assisted tools and the capabilities.

Cooling & Heating Load Calculations

So I'll start for the today's agenda and today's webinar topic. So the agenda is first we'll see what is meant by cooling and hitting load calculations why it matters the load calculation methods to calculate it then heat balance method which is gold standard as mentioned by ashri and why it is so then understanding ash 183 requirements [clears throat] what is the role of this standard its scope and the minimum requirements what which it puts for the this load calculation and how buildings is in compliance with ashray 193.

So going forward so first we'll see the cooling and heating load calculation why it matters. So as [clears throat] all you as a HVAC designers or engineers you might know that a best HVAC system is which can provide or maintain set temperature and humidity conditions for all your spaces. But what happens many a times is to ensure that it should maintain the better environment. People are not confident about whether it will perform its job or not. So it might happen that by adding factor of safety or by not having confidence on calculation people adds factor of safety and it leads to large amount of energy consumption and oversizing or undersizing of HVAC system may happen.

So from the studies of US energy department 48% of HVAC contributes the measure of the building energy consumption and if it oversizes that is a major factor in a global warming of our today's world and that is the challenge we are facing. So that's the issue we have. [clears throat] Then we'll see what is cooling and heating loads calculation. So as you may know about the spaces we wanted to maintain under temperature and 50% or whatever the design condition for humidity for human comfort or the equipment or industrial purpose you are designing your HVAC system to. So it starts from the solar load. So solar load is the major contributor for the buildings as solar loads load is coming through windows fenestration opaque fenestrations then from the temperature which is outside the building which is also driving temperaturedriven heat gains or heat losses based on your location and then internal gains also contribute.

Then infiltration because your space might not be fully airtight. Then ventilation. So whatever outdoor air you are coming to that also adds up heat or cold air from the outside. So based on your scenario then system generated things like fans may add heat or there are in inefficiencies that also adds to heating loads. So that is what cooling anti and all these heating all these loads HVAC system have to perform some operation to maintain your space that is nothing but your cooling or heating load.

So going forward so we'll see how to calculate this cooling load. So the first principle thing people go by using thumb rules or the simple calculations for the very small spaces or like low-rise buildings or residential buildings people can use simple formulas like Q UA delta T that is the only temperature difference which is driving heat inside your building. [snorts] But for larger buildings which are high-rise complex or in commercial buildings this may be inaccurate. So there are some methods like CLTD cooling load temperature difference method then radian time series method and heat balance method. So from all of these methods heat balance [clears throat] method is the gold standard method and which is accurate but it is complex. So it is difficult to calculate loads using heat balance method manually. So there are some softwares or some computerized programs are needed to do it.

The Heat Balance Method

So when we talk about ashray heat balance method we are talking about the most rigorous physics based way to calculate heating and cooling loads. At its core idea is actually simple. The idea is like your heat inside to heat outside. U heat inside should be equal to heat ounce outside and then storage of your Q storage. The all summation should be zero. That is the simple principle of it. The heat balance method takes this principle and it applies to everywhere like for your walls to your windows to your zone air itself or your internal mass within a space. So Q in Q out and how much heat is getting stored in that building component. So that is the principle. So it also accounts for time lag. So as you might know that every component has some heat storage capacity. So it stores heat and after some time it releases. So that also this heat balance method accounts for. So how it does is so these equations are solved numerically at each time step often hourly or subhourly maybe 10 minutes or 15 minutes of sub intervals.

We can calculate to determine how much heating and cooling is required to keep zone at its set point and humidity. So because it models the physics so completely ash identified is a gold standard in its fundamental handbook. So that is the main principle. So there are me methods available but this is the most effective method that you can look for. So before we dive into ash 183 so here is the physics explained how much it is complex. So as you can see the sample schematic diagram of one space is given how heat is conducted transmitted absorbed and transferred from one component to another component from the ceilings wall roofs.

Then air infiltration and what not. So no calculation method can capture every single interaction perfectly but some simplifications we may have to do. So if a method is oversimplifies this it will lead to inaccurate load calculation and if it go it goes for calculation for every component. So it will be impractical or computationally very heavy to calculate. So good news is that modern tools like Buildings AI which is backed up with EnergyPlus engine are built on the heat balance method which Astra recognizes. So that's what we look forward.

So understanding a 183. So 183 it doesn't specify that you should go with

ASHRAE 183 Requirements

Only one method but it suggest u hit balance method. So we'll look for what is the purpose and standard of the scope. So this standard doesn't establish doesn't say which method you should go for. It establishes minimum requirement for performing peak cooling and heating load calculations. So although there are many methods available to perform the intent of this standard is to establish minimum level of requirement that is inclusive and possible while it still being restrictive enough to make to mandate an appropriate level of care and accuracy and it is developed by ANC Ashray and ACCA. So these are the well-reputed institutions from the USA u so it is collaboratively efforts taken by these institutes and came up with this standard.

So we'll see what are the minimum requirements for the peak load calculation. So there are sections and subsections given in a document. I will not go into each sub section but I have listed down the measure criterias they have defined in the simplified. So the first criteria is designer should provide a well accurate inputs so that load there should not be any inaccuracies from input side. So weather data and indoor design conditions that should be a accurate like outdoor conditions temperatures, humidity, solar flux, location, the orientation of building and from indoor design conditions owners requirements the can be discussed with owners or owner have forwarded you in an email or any do document you have provided like sustainable [clears throat] I wanted to make my building sustainable. Or if your application is industrial clean room application, so owner's criteria might be my room should have a very least very lethal count or something like that. So based on owner's criteria your design should perform your design should be compliance with local codes like New York has its own code or

India has its own code so it should comply to that also and then comfort criteria. So whoever are the occupants there so it should be comfort criteria also it should meet. Then for the cooling loads how to calculate your cooling loads. So hourly and monthly analysis should be done because earlier how people are calculating they are calculating based on design days. So only 2 days or only few days they are considering based on designer's intent but [clears throat] peak can come at any hour of the year based on your orientation or your zone direction or your operation schedules that your building is operating at. So all the simulation should be done. Then convective and gradient gains should be considered. Then one of one major criteria is thermal mass effect is should be also captured.

Then heating load for heating load temperature heat losses you should account for and solar and internal gains should be excluded. So earlier in a 183 2014 if internal gains are constant so you can consider those as well. But from 2024 they have explicitly mentioned that internal gains also you should exclude for from your heating load calculations. Then infiltration effects whether it might be heat gain or heat loss you should consider. Then heat absorbing processes or equipments if your space has any like cold process equipments or refrigerant mainly then external heat gains for cooling load calculation external it requires external heat gains considering solar temperature-driven gains. If say your in your time when sun is very inclined then it is important to calculate heat coming through your glass or windows as well. Then time delay it should capture interior and exterior shading if present. Infiltration then internal gains occupants lighting equipment gains and its operational schedules and then system inefficiencies and psychrometric processes and leakages and losses you should consider. So that is a minimum criteria.

But this ash 183 mostly focuses on zone loads and u system loads for capacity and you cannot completely ne neglect system loads. So you have to account for system loads as well. So from all these criterias I have listed eight key requirement categories that software should comply. So to for your application or your simulation or your study or design you are doing. So yeah, so those are outdoor weather data. Indoor design condition should be accurately modeled. Solar radiations, heat gain component, thermal mass effect, occupancy and internal loads, heating load considerations and system load calculations.

Buildings AI & ASHRAE 183

So now we'll see how building CI is a compliant tool and how can you make your calc your design SH 183 compliant and you can confidently go and say that whatever load calculations I'm doing for my project is a 183 compliant. At the end designer have to sign the form that your calculations are 183 compliant. So will be explicitly showing you. So first based first thing is your outdoor air conditions and weather data should be accurate enough to model the behavior of your site or the temperature behavior and external weather conditions. So as you first create your project in buildings here and as you enter your building location the buildings automatically fetch the respective EPW files and DD files from the nearest weather station data center and it uses in its simulation. But if you have some custom requirement, users can also import a custom weather files to do your load calculation as well as it also note down your latitude and longitude location so that your solar radiation calculation should be accurate.

The next thing is indoor design conditions. As we said the as we saw the u requirements the indoor design conditions like your set points, humidity set points, your whether your space is has a dehumidification set point set point that you can mention in the space type details. Your heat gain comp components like your occupancy, your lighting load, your PL plenum loads, infiltration that you can mention here. You can also mention the sensible and laten bifur bifurcation of your loads. Then you can also upload or provide a schedules of your all these schedules for your all the equipments for occupancy as well as lighting and equipment and then your outdoor air condition requirement according to a 62.1 or if you have any custom requirements that you can mention in space type details so that your indoor design condition should be accurate and it will be compliant to SJ183.

So other than that we have 150 plus predefined space types which are compliant with standards like a 90.1 if you wanted to use that you can also use those predefined space types and go for calculations. The next thing is from a designer's perspective, the most important thing is accurately model the geometry which is necessary and should account for all the surfaces. So all the surfaces like windows, door, roofs, floors, all the surfaces it should include. On some occasions, ground contact of your floor is also necessary. For high thermal masks your ground may remove [clears throat] heat from your space during cooling load calculations. For solar load tracking your geometry should be correctly oriented. So we have one more option to reorient your geometry if you wants to. And for a baseline simulations you may want to rotate and check the what is the minimum energy usage you will get for the your building orientation you specify to then your geometry [clears throat] so from interoperatability perspective Buildings AI provides option ions to import your building model from Revit.

So we have a direct support from the Revit and if you have Autotodisk architectural model that also you can import to and we have a plug-in as preven tool. We have a AI agents which can extract your geometry from PDF and convert it into Revit model. So that you don't have to take any pro you should you need you can be assured that your geometry can be correctly modeled. [clears throat] So if your geometry has the external buildings the shading effect due to exter external buildings that buildings is capable to model like if you see this building it has it has a building side to it. So it is capable to model the external finestration. [clears throat] If your geometry has defined the blinds or drapes, it can model it is capable of modeling that as well. Then opaque building envelop and fenestration. So we'll talk to yeah.

So as it is using EnergyPlus in the back end we have both options whether you wanted to go for design day calculations or whether you wanted to go for the annual load calculation based on 8760 hours you can go for like and you'll get results like shown in graph here. So for every hour you'll get the hourly loads and from that maximum is a cooling peak and medium can be heating pig for every zone you'll get that. So the next thing is [clears throat] so that is about geometry. The next thing comes is accurate construction model. So if you are going for from a Revit import model. So if whatever the material you have provided in your Revit model, buildings air is capable to import proper thermal properties of those from those beam models. Also, if you wanted to change anything or if you wanted to try new materials, we have a library which has materials from different standard like a 189, a H90.1.

So, you can check for those materials and reapply those material to your geometry that is possible or even if you wanted to create a custom material that is also possible. So building provides the options option to define your material layer by layer like you see in this image and you can provide detailed properties like thickness conductivity, density, specific heat, solar absorptance. So you can see here when you model your geometry and your materials accurately your solar radiation calculations your heat gain components and thermal mass effects all things will be getting captured for your calculations.

The next thing is the accurate system modeling. For accurate system modeling. Currently we have a standard 14 HVAC systems supported through which you can run simulations like AHUS with chilled water sources. Then split ahus, cav, vab. Then terminal units like variable refrigerant flow, four pi fan column unit, active chilled beam, passive chilled beam, radiant panels, unit ventilators, unit heaters, packaged terminal air condition, package terminal heat pumps. Then water source heat pumps all these are supported with plants are also present.

So you can connect those air AHUS with the plants hot water plant, shed water plant, condenser plant and variable refinement flow plant based on your sources and model accurately model your system so that your system loads or gains or losses can be accurately modeled. Also in this quarter end of this quarter we are coming up with the exciting feature that is the aside from those standard HVAC systems you will be able to create the custom HAR systems of your needs from the canvas we are coming up with. So this is the new feature we are coming HAR canvas. So in pitch you can create a detailed HAX system of your needs.

privacy sorry to interrupt. I see Nish's hands raised. So Nish please message me in the chat whatever your facing so we can address that. Meanwhile we'll continue with the webinar. Thanks. Thanks. So that's about the buildings workflow and how it complies with the

Workflow Demonstration

Standard. So we'll see the demo of buildings here for it's a couple of minute demo. So you'll get idea about the software and how to use it. So first it starts with the your project dashboard. So you create your project, provide the primary information of your project, provide site location. Then import your building model or start from by sketching as I already have my detailed Revit model. So we have a Revit plugin on at store that you can download and check that your Revit model is it ready for load and energy simulation or not.

Then I import my Revit model. So you can segregate your envelope components floor wise, direction wise or its component types. You can individually assign materials or with bulk selection as well. Same for space types. So that my internal design conditions and loads should get considered accurately. The next thing is zoning. So you can group your spaces under different zones conditioned or unconditioned. Then after joining you can submit your building configuration. The next step is the HVAC system.

So I'm going with standard HVAC system. So my zones are now visible in the on the left side. I can assign my I can create a shells and assign to those zones and then I can look for the plants. So these are the predefined plants but if you wanted to change the parameters and create new that is also possible. Then I can run road simulation. So it will take 10 minutes to complete the simulation and then you will get your loads zone wise, systemwise or facility wise and then a bifurcation of your load with respect to envelope components or internal gains.

Same for energy. Select your building configuration, HY configuration and then weather file. Then will take couple of minutes to run simulation and then we'll get results. So here you can see the I'll I'm getting component wise as well as month wise data of energy and then we have a assistant a report assistant as simulation is completed using EnergyPlus engine the vast amount of data has been generated you may not want to go through all that data. So whatever loop calculation reports you want you can ask through this report assistant and it can able to generate the requirements you provided from the data from the simulation results those are generated.

So then we have a data hub feature so you can upload so that you can upload your all your project data at a single place. These are like project management tools. Version wise, it is able to [clears throat] store your data. You can download your models files anytime. So that is so that is about building.

Compliance Summary & Closing

So next thing is in summary we'll see the compliance of compliance with a 183 of buildings here. So buildings supports the weather data and indoor design conditions as asked by a 183 cooling load methodology also. Then external and internal heat gains. It is capable to model as the standard suggest heating load heating load methodology. So it credits for solar heat gains, infiltration as well as peak temperature driven gains.

Currently we are in a progress to support cold process or cold process related equipments. So it partially complies. Then system cooling and heating loads. So for from systems side it accounts for psychrometric calculations, outdoor air ventilation loads, your fan and pump heat gains. Then diversity of lighting equipment and equipment and its behavior with respect to your HVAC system that also it is capable of modeling. Currently it it's not we don't have an option to provide you piping dirt leakage or damper leakage but in the near future will it will come up with it.

So that's it from my side. Yeah privacy over to you. Thanks.

Next Steps & Q&A

Thanks. Thanks privacy for the insightful session and the walk through of workflow demonstration of the app. So we are towards the end of the webinar now and what's next? So you can visit simulationup.com. You can request a demo meeting with our product expert and ask your you know you can interact with them and discover how the app can improve your productivity of your team and how it can support your sustainability goals and things. So, and alternately you can start your free trial. Free trial comes within a 15 days accessibility and yeah so on top of this we are we have a student trial subscription. I see a lot of students in the list right now. So I see their profile. So, so for them we have extended trial period of 2 months and increased credits you know simulation credits and with this in the context of you know current design competition Ashray design competition 2026 so students can benefit whoever is participating in HVAC design calculations or HAC system selection or the net zero energy design. So they can use our platform to meet the demands of the submission the list of submission requirements you can see and even the first one peak loading

Peak load calculations as per ash 180 standard. So this is also one of the requirements. So that is also satisfied. So you can utilize this so you can yeah can you can see the QR code Arita next. So you can scan and start your student trial journey or you can book the you know student free trial or request a demo call. We'll help you out with getting started with the platform. So with that yes we are coming to the end of the session. So you can post your questions in the chat window and we already received few questions. privacy next I guess this is the end.

Yeah. So I have a few questions. Okay u so which EnergyPlus version are you using? Can you import IDF files? Are there any comments? Yes. Yeah IDF files. Yeah the from the development help of our development team you can provide us IDF files and we can support those but from directly from the app there's no option to import files so right now the supported inputs are from Revit model or AutoCAD architectural model or if you have a floor plan you can start from scratch.

So these are the options and it has the app has a inbuilt sketcher so plan floor plan sketcher so that you can use and use it. So, idea file as privacy says that is kind of you know u it needs some support backend support to you know have it in the so any comments on the EnergyPlus version everything EnergyPlus version 25.1 we are supporting oh okay thanks so hope that answers and there is one more question from privacy for the energy simul calcation. How can we detail values or daily yearly profiles?

How does the agent help us quickly update these kind of inputs? Yeah. Okay. So, agentic as I'll go to the slide. Okay. So, agent how it supports is we have a building assistant feature in the application. So how it helps is you can ask if you are unsure about your material of your building or which material you should use for make your building sustainable. So you can directly go and ask building assistant that I my project is at this location and I'm in this climate zone and which material I should use. So it can able to suggest you materials and and even with your permission it can directly go and assign to those envelope components. Same for the space types.

There are tools we are coming up with and developing like if you have your data in spreadsheets or PDF or schedules so you can provide and whether it might be in your format as well. It might not be available in buildings format but with the help of AI it can extract that data and directly go and apply to your building model. So that's how it supports. Also we are also coming up with the agentic workflow that automatically suggest which orientation your building should be which material it should have so that your building should be sustainable or if you are applying for lead compliant lead certification that also it will be able to help. So that's how we are moving forward. Yeah, thanks. Thanks.

So u we had few questions during the webinar. I answered them but I just want to read it out so that you know others can also benefit from those questions. So this was a question from privacy again we mentioned you do full building model full building modeling simulation and how does this compare with established tools such as IEES? Yes. The building a has you know it's a full building model simulation so it includes peak load calculations energy analysis and CFD part right now and we are bringing daylight and other you know LCA so all sort of things we are bringing in the next release. So in terms of methodology what we follow and the IE follow is same heat balance method is implemented they have their own engines Apache and then we use the department of energy back EnergyPlus engine. So in terms of you know physics calculations the results are same. So where we bring the difference is in the you know workflow to make it more easy and easy to use. So existing tools are kind of you know inter has some interoperability pain points and some manual efforts in setting up the problem. It has steep learning curves as also. So we are

Addressing those issues pain points with help of AI agents. So that was the question. There was one more question from privacy. Does this tool perform astray heat balance method? I guess that is answered. So yes we use EnergyPlus engine and which in the back end so which uses ashray heat balance method for load calculation and energy solution? Yes. So is there any is any part of this calculation using AI or just the energy passing? Oh okay. Yes. The AI is used only for the workflow improvement.

And the problem setup and things the EnergyPlus engine is the that is the pure part like physics is completely taken care by the EnergyPlus engine. So no calculation part is you know used for EnergyPlus engine. Once the calculation is done, the results are available, then the AI comes in. Then again the AI can come in and extract the results and put it in a nice autogenerated report which you can you know chat with that and interact with the AI assistant and modify the format and template to suit your you know design teams and yeah so that so those are the questions for now I guess there was there is one more question let me see from Lewis. For the energy simulation, how can we deter I guess this is the same question? Okay, this these questions are already answered.

What is the level of EnergyPlus integration? I mean can we use EMS etc to do runtime control? privacy any comments on that? Yeah, I need to check with the technical team. So currently I'm also not sure but will get back to you. Sure. Sure. So we have your email id as well. We'll connect with you and answer these questions. So can I compare two ahu with different set point? Yeah that is question from yes you can compare two with different set points. Yes.

Okay. Thanks. Thanks for this interaction. This is making it very lively things. So if you have more questions, please feel free to post those or in the chat window. Meanwhile, in the chat window, I'll share my email id so you can email me all the queries and then for further assistance and stuff. So this is our website so we can visit and you know start your building the journey. So I don't see any more questions coming up. So thanks everyone.

Thanks privacy for sharing your you know knowledge about HT 183 and things. Yes. Aditi you would like to Yeah. By the way we are also open and we are organization of 200 plus engineers from CAD and the simulation background with sustainability and AEC industry expertise. So if you have any custom requirements or projects in this field we are open to discuss and for buildings and simulationHub we can leverage those APIs and provide you your custom requirements as well. So yeah I curious to know your requirements as well. Yeah, thanks.

That's what I wanted to say. And stay tuned, follow our social media handles for future webinar announcement and any exclusive offers and things. So thanks everyone for staying till the end of the webinar. I appreciate your time. Thank you everyone. See you in the next webinar. Bye-bye. Thank you.

Read the full transcript 5700+ words, 8 chapters. Tell us who you are, and the transcript and the recording open.
Transcript

Privacy modifications

What we changed in the automatic transcript of this recording.

Names removed

To protect the privacy of the speakers, the attendees and anyone else mentioned, no person's name is in this transcript. Each name is shown as privacy instead (16 in this transcript). The recording itself is unchanged.

Other modifications

  • Made from the automatic captions of the recording.
  • Filler words (such as “uh” and “um”), words said twice in a row and sound notes such as [music] removed.
  • Product names, standards and technical terms the captions heard wrongly corrected.
  • Arranged in paragraphs under the recording's chapters; each time plays the recording from that moment.

The transcript may contain mistakes; the recording is the reference.

Keep watching

More webinars

See all webinars
Buildings AIOctober 28, 2026

IGBC Green Building Certification

Watch this webinar to learn how building performance analysis contributes to achieving IGBC Green Building certification and optimizing sustainable design strategies. Watch the recording
Buildings AISeptember 2, 2026

Buildings AI 2027 Release Event

Watch the recording of the Buildings AI 2027 Release Event as we unveil the latest capabilities, demonstrate new workflows, and explore how engineering teams can build models faster, reduce repetitive work, and create more connected building energy workflows. Watch the recording
Buildings AIJune 25, 2026

AI-Assisted HVAC Systems Modeling for Load and Energy Optimization using Buildings AI

Watch this webinar to learn how the HVAC Canvas AI Assistant in Buildings AI enables automated HVAC network modeling through a conversational, agentic workflow — eliminating manual configuration and delivering faster, more efficient system design without the complexity of traditional tools. Watch the recording

Cookie settings

Choose which cookies we may use. Strictly necessary cookies are always on. You can change your choice at any time with "Cookie settings" at the bottom of every page. Read our Cookie Policy.

Newsletter

Newsletter Subscription

Subscribe to simulationHub newsletter to get regular updates on announcements, blogs, press releases, etc.

Name

By sending this form, you agree to our Privacy Notice. Along with your details, we receive the address of the page you are on and your IP address.